ANTRACK V2

$5,888.00

Specifications
1Set 24kW 4 Hydro-cooling Miner Rack I 80℃ Heating Capacity

ANTRACK V2 delivers advanced 24kW hydro-cooling for ANTMINER Hydro miners with an external heat pump, 80°C heating output, and industrial-grade reliability.

Extra Features
  • Premium Quality
  • Secure Payments
  • Satisfaction Guarantee
  • Worldwide Shipping
  • Money Back Guarantee

NOTE:

  • The ANTRACK V2 is designed for simultaneous use with Hydro-cooling ANTMINER models, including 4× ANTMINER Hydro, 4× ANTMINER U2 Hydro, or 2× ANTMINER U3 Hydro units.
    After placing your order, kindly contact your Sales Manager, Customer Service Robot, or email support@bitmain.com.vc

Purchasing Guidelines:

  1. The ANTRACK V2 is recommended for use with BITMAIN Hydro-cooling ANTMINERs to ensure optimal performance.
  2. The listed product price excludes shipping fees, customs duties, and applicable taxes.
  3. After an order is submitted, BITMAIN does not accept cancellations, refunds, or changes (including model or batch changes).
  4. Product images are for reference only; the final shipped version shall prevail.
  5. Contact your Sales Manager or Customer Service Robot to confirm shipping fees, delivery arrangements, and lead times.

Shipping Details:

  1. Shipments are fulfilled on a first-paid, first-shipped basis once full payment is received by BITMAIN.
  2. Spot shipping for ANTRACK V2 begins January 2026.
  3. Buyers are responsible for any customs delays, duties, or returned shipments due to incomplete or incorrect documentation.
  4. It is strongly recommended to review local customs clearance requirements and prepare all documents in advance to avoid delays or additional costs.

Warranty:

  • The ANTRACK V2 includes a 365-day warranty, starting from the shipping date.
  • BITMAIN will cover the one-way shipping cost for replacement units during the warranty period.
  • Warranty applies only to the original purchaser who bought directly from BITMAIN. If resold, warranty responsibility transfers to the reseller.
  • Improper use, non-compliant installation, operation outside specified conditions, or unauthorized modifications void the warranty.
  • For complete warranty terms, please refer to the official BITMAIN Terms & Conditions.

Operational Notes

  • The ANTRACK V2 supports:
    4× ANTMINER (Hydro), or
    4× ANTMINER U2 Hydro, or
    2× ANTMINER U3 Hydro

  • Maximum load: 24 kW mining cabinet.
  • External cooler (heat pump) heating capacity: 32 kW with up to 80°C output water temperature.
  • Recommended operating environment: Ambient temperature –20 °C to 40 °C, water pressure ≤ 3.5 bar.
  • Maintain proper ventilation and install the external cooler outdoors in a well-ventilated area.
  • Maximum recommended installation distance between cabinet and cooler: 50 m.
  • Working fluid: 10% antifreeze, with water conductivity requirements per BITMAIN specifications (<20 μs/cm at initial startup).

Each ANTRACK V2 Set Includes:

  • Mining cabinet with 4 rack slots
  • External cooler (heat pump system)
  • Water pump (450 W for cabinet, 180 W for cooler)
  • Plate heat exchanger
  • Fans for heat pump system
  • Required internal piping and connectors (DN20)

Additional Items Required for Installation:

  • Three-phase, five-core 380–415 V AC power cable (sized per electrical standards)
  • Ethernet cable (RJ45)
  • Antifreeze solution (10%), approx. volume based on system installation
  • Proper mounting area with required clearances

 

Weight300 kg
Dimensions2260 × 1130 × 780 mm
Model NO.

ANTRACK

Model

V2

Capacity

4 units ANTMINER (Hydro) or
4 units ANTMINER (U2 Hydro) or
2 units ANTMINER (U3 Hydro)

Part 1: Mining Cabinet / Size

Size (Length*Width*Height), mm (without package) – 1200*600*1300
Size (Length*Width*Height), mm (with package) – 1460*1330*780

Part 1: Mining Cabinet / Power

Power supply AC input voltage, Volt – 380~415
Power supply AC input frequency range, Hz – 50~60
Power supply AC Input current, Amp – 63

Part 1: Mining Cabinet / Pump

Rated power, W – 450
Noise, dBA@1m – 60
Lift, m – 19
Size (Length*Height*Thickness), mm – 360*210*268

Part 1: Mining Cabinet / Plate Heat Exchanger

Maximum heat exchange power, kW – 30
Size (Length*Width* Height), mm – 305*106*64
Diameter of water pipe connector, mm – DN20

Part 2: External Cooler / Hardware Configuration

Size (Length*Width*Height), mm (without package) – 1340*570*1330
Size (Length*Width*Height), mm (with package) – 1490*590*1495
Net weight, kg (without package) – 235
Gross weight, kg (with package) – 248

Part 2: External Cooler / Power supply

Heating Capacity (typical), kW – 32
Compressor Input (typical), kW – 8
EER (typical) – 3.0
Sound Level, Db(A) – 50
Refrigerant – R290
Heating water outlet temperature, °C – 80

Part 2: External Cooler / Fan

Rated power, W – 500
Noise, dBA@1m – 50
Size (Length*Height*Thickness), mm – 551*551*160

Part 2: External Cooler / Water pump

Rated power, W – 180
Noise, dBA@1m – 30
Size (Length*Width* Height), mm – 130*551*129

Part 2: External Cooler / Environment requirements

Ambient temperature, °C: -20~40
Water flow, L/min: 32.0~40.0 (Cabinet side)
Water pressure, bar: ≤3.5
Working fluid: Antifreeze (10%)
Installation distance, m: 50
Liquid PH: 7.8~8.5
Storage temperature, °C: -20~70
Operation humidity(non-condensing), RH: 10~90%

Origin

China

Release

January 2026

Weight

Net weight, kg (without package) – 130
Gross weight, kg (with package) – 185